| Model |
Description |
Additional Information |
460:
 |
The 460 hand held oscilloscope features a 3” x 3” cold cathode
fluorescent display providing test data in a clear easy to see format. The
cursor readout function allows the width and amplitude of a signal to be
measured precisely instead of trying to figure it out manually.
- 4,000 count true RMS DMM, CACV, DCV ohms and continuity buzzer need optional
adapters for current measurement
- 20 MHz Bandwidth
- Cursor Readout
- Decibels
- Pre and Post Triggering
- Trend Mode
- Dual Input
- Real Time Sample Rate
- Bright LCD Backlight
- Optically Isolated RS232 Output
- Continuous Autoset
- cULus 61010-1
- CAT II – 1000V, CAT III – 600V
- 3 Year Limited Warranty
|
Product Sheet
Instruction Manual
Specifications
Applications
Tech Tips
FAQs

|
440:
 |
The hand held 440 scope plus features an easy to use combination of a
single input 1 MHz oscilloscope with True RMS DMM.
- True RMS Auto Ranging DMM offers increased accuracy over average responding
multimeters
- 1MHz Oscilloscope can be used to view power signals to determine quality as
well as correct amplitude and frequency, assisting in finding and preventing
problems
- Trend Mode enables surges and dropouts to be graphed.
- Communication to a PC using optional RS-232 cable and software
- cULus 61010-1
- CAT II – 1000V, CAT III – 600V
- 3 Year Limited Warranty
|
Product Sheet
Instruction Manual
Specifications
Applications
Tech Tips
FAQs

|
196:
 |
0-24 mA output built in for process loop calibration, 0.05% accuracy,
50,000 counts, DMM with separate fuse and battery compartment
- Process DMM with 0 to 24mA output
- 50,000 count display
- 0.05% DCV basic accuracy
- 0 to 750 ACV; max resolution 100uV
- 0 to 1,000 DCV; max resolution 0.001mV
- 0 to 50MΩ; max resolution 0.01Ω
- Audible continuity
- AC/DC amps up to10 amps; max resolution 0.01uA
- Analog bar graph
- Min/Max
- Data hold
- Power off
- Separate fuse and battery compartment
- cULus 61010-1
- CAT II-1000VDC, 750VAC, CATIII-600V
- Limited Life time Warranty
|
Product Sheet Instruction Manual
Specifications
Applications
Tech Tips
FAQs

|
194:
 |
CAT IV 600 ACV, data logging, 0.05% accuracy, 50,000 count, True RMS
DMM with separate fuse and battery compartment
- Data logging
- 50,000 count display
- 0.05% DCV basic accuracy
- True RMS
- Inductance
- Frequency
- Capacitance
- 0 to 750 ACV; max resolution 100uV
- 0 to 1,000 DCV: max resolution 0.001mV
- 0 to 50MΩ; max resolution 0.01Ω
- Audible continuity
- AC/DC amps up to10 amps; resolution 0.01 uA
- Analog bar graph
- Min/Max
- Data hold
- Power off
- Separate fuse and battery compartment
- cULus 61010-1
- CATIII-1000VC, CATIII-1000V, CAT IV-600V, CAT III 1000V
- Limited Life time Warranty
|
Data Sheet
Instruction Manual
Specifications
Applications
Tech Tips
FAQs

|
192:
 |
Data logging, 0.05% accuracy, 50,000 count, True RMS DMM with
separate fuse and battery compartment.
- Data logging
- 50,000 count display
- 0.05% DCV basic accuracy
- True RMS
- Inductance
- Frequency
- Capacitance
- 0 to 750 ACV; max resolution 100uV
- 0 to 1,000 DCV: max resolution 0.001mV
- 0 to 50MΩ; max resolution 0.01Ω
- Audible continuity
- AC/DC amps up to10 amps; resolution 0.01 uA
- Analog bar graph
- Min/Max
- Data hold
- Power off
- Separate fuse and battery compartment
- cULus 61010-1
- CAT II-1000VDC, 750VAC, CAT III – 600V
- Limited Life time Warranty
|
Product SheetInstruction Manual
Specifications
Applications
Tech Tips
FAQs

|
183A:
 |
True RMS DMM with temperature, capacitance, duty cycle, &
low-pass filter
- 4,000 count
- True RMS for more accurate measurements
- Auto/manual ranging
- Temperature measurement
- Duty cycle to measure the amount of time the motor is on
- Low pass filter for noisy environments
- Separate fuse (2) and battery compartment
- Auto power off
- IR serial interface
- cULus 61010-1
- CAT II – 1000V, CAT III – 600V
- 3 Year Limited Warranty
Applications
- Test run and start capacitors
- Measure ambient and duct temp.
- Test control (thermostat, thermocouple, flame safety) and line voltages
- Measure resistance and test for continuity
- Line current up to 10 amps (in series)
|
Data Sheet
Instruction Manual
Specifications
Applications
Tech Tips
FAQs

|
163:
 |
Full size DMM with analog bar graph; 1,000 DC volts and 750 AC volts;
0.5% DCV basic accuracy
- 3260 count display
- 0.5% DCV basic accuracy
- 0 to 750 ACV; max resolution 1mV
- 0 to 1,000 DCV; max resolution 0.1mV
- 0 to 32.6MΩ; max resolution 0.1Ω
- Audible continuity
- 0 to 10 amps AC/DC; max resolution 0.1uA
- Analog bar graph
- Data hold
- Sleep mode/auto off
- cULus 61010-1
- CAT II – 1000V, CAT III – 600V
- 3 Year Limited Warranty
|
Product Sheet
Instruction Manual
Specifications
Applications
Tech Tips
FAQs

|
153:
 |
Full size DMM with capacitance; 1,000 DC volts and 750 AC volts; 0.5%
DCV basic accuracy
- 4,000 count display
- 0.5% DCV basic accuracy
- 0 to 750 ACV; max resolution 0.1mV
- 0 to 1,000 DCV; max resolution 0.1mV
- 0 to 40MΩ; max resolution 0.1Ω
- 0 to 10 amps AC/DC; 0.1uA resolution
- Data hold
- cULus 61010-1
- CAT II – 1000V, CAT III – 600V
- 3 Year Limited Warranty
|
Product Sheet
Instruction Manual SpecificationsApplications
Tech Tips
FAQs

|
133:
 |
Large easy to read display in full size DMM; 1,000 DC volts and 750
AC volts; 0.5% DCV basic accuracy
- Large easy to read 2,000 count display
- 0.5% DCV basic accuracy
- 0 to 750 ACV; max resolution 1mV
- 0 to 1,000 DCV; max resolution 0.1mV
- 0 to 20MΩ; max resolution 0.1Ω
- 0 to 10 amps AC/DC; max resolution 0.1uA
- Data hold
- cULus 61010-1
- CAT II – 1000V, CAT III – 600V
- 3 Year Limited Warranty
|
Product Sheet
Instruction Manual
Specifications
Applications
Tech Tips
FAQs

|
126:
 |
Compact autoranging DMM with 0.3% DCV basic accuracy and 400mA AC/DC
range
- 4,000 count display
- 0.3% DCV basic accuracy
- 0 to 600 volts AC/DC; max resolution 0.1V
- 0 to 40MΩ resistance; max resolution 0.1Ω
- Audible continuity
- 0 to 400 mA amps AC/DC; max resolution 0.01mA
- Autoranging
- Min/Max
- Data Hold
- Sleep mode/auto off
- cULus 61010-1
- CAT II – 1000V, CAT III – 600V
- 3 Year Limited Warranty
|
Product Sheet Instruction Manual
Specifications
Applications
Tech Tips
FAQs

|
122:
 |
Compact DMM with adapter range for optional accessories, 0.5% DCV
basic accuracy
- 2,000 mvDC (2 DCV) adapter range
- 2,000 count display
- 0 to 600 volts AC and DC
- 0 to 2,000 ohms
- Audible continuity
- 10 MOHM internal impedance
- 0.5 % DCV basic accuracy
- cULus 61010-1
- CAT II – 1000V, CAT III – 600V
- 3 Year Limited Warranty
|
Product Sheet
Instruction Manual
Specifications
Applications
Tech Tips
FAQs

|
120:
 |
Compact, manual ranging, basic DCV 0.5% accuracy DMM
- 2,000 count display
- 0 to 600 volts AC and DC
- 0 to 2,000 ohms
- Audible continuity
- 10 MOHM internal impedance
- 0.5% DCV basic accuracy
- cULus 61010-1
- CAT II – 1000V, CAT III – 600V
- 3 Year Limited Warranty
|
Product Sheet
Instruction Manual
Specifications
Applications
Tech Tips
FAQs

|
100:

|
No more guessing what range to switch your meter to — the TPI 100
does it automatically!
|
Product Sheet
Instruction Manual
Specifications
Applications
Tech Tips
FAQs

|