Multimeters (DMMs)

TPI offers Digital Multimeters to fit a wide range of applications including electrical, electronic, commercial, HVAC/R, and industrial.
Model Description Additional Information
460:
460 Multimeters (DMMs)
The 460 hand held oscilloscope features a 3” x 3” cold cathode
fluorescent display providing test data in a clear easy to see format. The
cursor readout function allows the width and amplitude of a signal to be
measured precisely instead of trying to figure it out manually.

  • 4,000 count true RMS DMM, CACV, DCV ohms and continuity buzzer need optional
    adapters for current measurement
  • 20 MHz Bandwidth
  • Cursor Readout
  • Decibels
  • Pre and Post Triggering
  • Trend Mode
  • Dual Input
  • Real Time Sample Rate
  • Bright LCD Backlight
  • Optically Isolated RS232 Output
  • Continuous Autoset
  • cULus 61010-1
  • CAT II – 1000V, CAT III – 600V
  • 3 Year Limited Warranty
Product Sheet
Instruction Manual


Specifications

 

 

 

Applications

 

Tech Tips

FAQs

 

RoHS Multimeters (DMMs)

 

440:
440 Multimeters (DMMs)
The hand held 440 scope plus features an easy to use combination of a
single input 1 MHz oscilloscope with True RMS DMM.

  • True RMS Auto Ranging DMM offers increased accuracy over average responding
    multimeters
  • 1MHz Oscilloscope can be used to view power signals to determine quality as
    well as correct amplitude and frequency, assisting in finding and preventing
    problems
  • Trend Mode enables surges and dropouts to be graphed.
  • Communication to a PC using optional RS-232 cable and software
  • cULus 61010-1
  • CAT II – 1000V, CAT III – 600V
  • 3 Year Limited Warranty
Product Sheet


Instruction Manual

Specifications 

Applications 

Tech Tips

FAQs

 

RoHS Multimeters (DMMs)

196:
196 Multimeters (DMMs)
0-24 mA output built in for process loop calibration, 0.05% accuracy,
50,000 counts, DMM with separate fuse and battery compartment

  • Process DMM with 0 to 24mA output
  • 50,000 count display
  • 0.05% DCV basic accuracy
  • 0 to 750 ACV; max resolution 100uV
  • 0 to 1,000 DCV; max resolution 0.001mV
  • 0 to 50MΩ; max resolution 0.01Ω
  • Audible continuity
  • AC/DC amps up to10 amps; max resolution 0.01uA
  • Analog bar graph
  • Min/Max
  • Data hold
  • Power off
  • Separate fuse and battery compartment
  • cULus 61010-1
  • CAT II-1000VDC, 750VAC, CATIII-600V
  • Limited Life time Warranty
Product Sheet Instruction Manual 

Specifications

Applications

Tech Tips

FAQs

 

RoHS Multimeters (DMMs)

194:
194 Multimeters (DMMs)
CAT IV 600 ACV, data logging, 0.05% accuracy, 50,000 count, True RMS
DMM with separate fuse and battery compartment

  • Data logging
  • 50,000 count display
  • 0.05% DCV basic accuracy
  • True RMS
  • Inductance
  • Frequency
  • Capacitance
  • 0 to 750 ACV; max resolution 100uV
  • 0 to 1,000 DCV: max resolution 0.001mV
  • 0 to 50MΩ; max resolution 0.01Ω
  • Audible continuity
  • AC/DC amps up to10 amps; resolution 0.01 uA
  • Analog bar graph
  • Min/Max
  • Data hold
  • Power off
  • Separate fuse and battery compartment
  • cULus 61010-1
  • CATIII-1000VC, CATIII-1000V, CAT IV-600V, CAT III 1000V
  • Limited Life time Warranty
Data Sheet
Instruction Manual

Specifications

Applications

Tech Tips

FAQs

 

RoHS Multimeters (DMMs)

 

 

192:
192 Multimeters (DMMs)
Data logging, 0.05% accuracy, 50,000 count, True RMS DMM with
separate fuse and battery compartment.

  • Data logging
  • 50,000 count display
  • 0.05% DCV basic accuracy
  • True RMS
  • Inductance
  • Frequency
  • Capacitance
  • 0 to 750 ACV; max resolution 100uV
  • 0 to 1,000 DCV: max resolution 0.001mV
  • 0 to 50MΩ; max resolution 0.01Ω
  • Audible continuity
  • AC/DC amps up to10 amps; resolution 0.01 uA
  • Analog bar graph
  • Min/Max
  • Data hold
  • Power off
  • Separate fuse and battery compartment
  • cULus 61010-1
  • CAT II-1000VDC, 750VAC, CAT III – 600V
  • Limited Life time Warranty
Product SheetInstruction Manual 

Specifications 

Applications 

Tech Tips 

FAQs 

RoHS Multimeters (DMMs)

183A:
183A Multimeters (DMMs)
True RMS DMM with temperature, capacitance, duty cycle, &
low-pass filter

  • 4,000 count
  • True RMS for more accurate measurements
  • Auto/manual ranging
  • Temperature measurement
  • Duty cycle to measure the amount of time the motor is on
  • Low pass filter for noisy environments
  • Separate fuse (2) and battery compartment
  • Auto power off
  • IR serial interface
  • cULus 61010-1
  • CAT II – 1000V, CAT III – 600V
  • 3 Year Limited Warranty
    Applications
  • Test run and start capacitors
  • Measure ambient and duct temp.
  • Test control (thermostat, thermocouple, flame safety) and line voltages
  • Measure resistance and test for continuity
  • Line current up to 10 amps (in series)
Data Sheet
Instruction Manual     

Specifications      

Applications  

Tech Tips  

FAQs

RoHS Multimeters (DMMs)

 

 

 

 

 

163:
163 Multimeters (DMMs)
Full size DMM with analog bar graph; 1,000 DC volts and 750 AC volts;
0.5% DCV basic accuracy

  • 3260 count display
  • 0.5% DCV basic accuracy
  • 0 to 750 ACV; max resolution 1mV
  • 0 to 1,000 DCV; max resolution 0.1mV
  • 0 to 32.6MΩ; max resolution 0.1Ω
  • Audible continuity
  • 0 to 10 amps AC/DC; max resolution 0.1uA
  • Analog bar graph
  • Data hold
  • Sleep mode/auto off
  • cULus 61010-1
  • CAT II – 1000V, CAT III – 600V
  • 3 Year Limited Warranty
Product Sheet
Instruction Manual 

Specifications

Applications

Tech Tips   

FAQs

RoHS Multimeters (DMMs)

 

 

153:
153 Multimeters (DMMs)
Full size DMM with capacitance; 1,000 DC volts and 750 AC volts; 0.5%
DCV basic accuracy

  • 4,000 count display
  • 0.5% DCV basic accuracy
  • 0 to 750 ACV; max resolution 0.1mV
  • 0 to 1,000 DCV; max resolution 0.1mV
  • 0 to 40MΩ; max resolution 0.1Ω
  • 0 to 10 amps AC/DC; 0.1uA resolution
  • Data hold
  • cULus 61010-1
  • CAT II – 1000V, CAT III – 600V
  • 3 Year Limited Warranty
Product Sheet
Instruction Manual  SpecificationsApplications

Tech Tips

FAQs

RoHS Multimeters (DMMs)

 

133:
133 Multimeters (DMMs)
Large easy to read display in full size DMM; 1,000 DC volts and 750
AC volts; 0.5% DCV basic accuracy

  • Large easy to read 2,000 count display
  • 0.5% DCV basic accuracy
  • 0 to 750 ACV; max resolution 1mV
  • 0 to 1,000 DCV; max resolution 0.1mV
  • 0 to 20MΩ; max resolution 0.1Ω
  • 0 to 10 amps AC/DC; max resolution 0.1uA
  • Data hold
  • cULus 61010-1
  • CAT II – 1000V, CAT III – 600V
  • 3 Year Limited Warranty
Product Sheet
Instruction Manual

Specifications

Applications

Tech Tips  

FAQs

 

RoHS Multimeters (DMMs)

 

 

 

126:
126 Multimeters (DMMs)
Compact autoranging DMM with 0.3% DCV basic accuracy and 400mA AC/DC
range

  • 4,000 count display
  • 0.3% DCV basic accuracy
  • 0 to 600 volts AC/DC; max resolution 0.1V
  • 0 to 40MΩ resistance; max resolution 0.1Ω
  • Audible continuity
  • 0 to 400 mA amps AC/DC; max resolution 0.01mA
  • Autoranging
  • Min/Max
  • Data Hold
  • Sleep mode/auto off
  • cULus 61010-1
  • CAT II – 1000V, CAT III – 600V
  • 3 Year Limited Warranty
Product Sheet Instruction Manual  

Specifications  

Applications 

Tech Tips   

FAQs

RoHS Multimeters (DMMs)

122:
122 Multimeters (DMMs)
Compact DMM with adapter range for optional accessories, 0.5% DCV
basic accuracy

  • 2,000 mvDC (2 DCV) adapter range
  • 2,000 count display
  • 0 to 600 volts AC and DC
  • 0 to 2,000 ohms
  • Audible continuity
  • 10 MOHM internal impedance
  • 0.5 % DCV basic accuracy
  • cULus 61010-1
  • CAT II – 1000V, CAT III – 600V
  • 3 Year Limited Warranty
Product Sheet
Instruction Manual   

Specifications

Applications

Tech Tips

FAQs

RoHS Multimeters (DMMs)

 

 

120:
120 Multimeters (DMMs)
Compact, manual ranging, basic DCV 0.5% accuracy DMM

  • 2,000 count display
  • 0 to 600 volts AC and DC
  • 0 to 2,000 ohms
  • Audible continuity
  • 10 MOHM internal impedance
  • 0.5% DCV basic accuracy
  • cULus 61010-1
  • CAT II – 1000V, CAT III – 600V
  • 3 Year Limited Warranty
Product Sheet


Instruction Manual

Specifications

Applications

Tech Tips

FAQs

RoHS Multimeters (DMMs)


100:
100 Multimeters (DMMs)
No more guessing what range to switch your meter to — the TPI 100
does it automatically!

Product Sheet


Instruction Manual


Specifications


Applications

Tech Tips


FAQs

RoHS Multimeters (DMMs)